Information
Search

Changer Sensor KIDDE 5DCO

Ražotājs: KIDDE
Modelis: Czujnik czadu KIDDE 5DCO
Preces kods: 14-33018

Brief Attributes


See all attributes

23,82€
Atlaide tiek piemērota tikai fiziskām personām.
Atlaide ir spēkā no 25.01.2021 līdz 01.03.2021

  • Pieejamība: Noliktavā
  • Skaits > 5

Paredzamais piegādes laiks no 06-08-2025 līdz 11-08-2025 datumam
Šī prece no noliktavas brauc uz veikalu līdz 10 darba dienām pēc apmaksas saņemšanas.

Sūtījuma sekošanas sistēma!

Sūtījuma sekošanas sistēma!

Tagad jūs varat ērti sekot savam sūtījumam.

Apmaksa ar bankas karti onlainā!

Apmaksa ar bankas karti onlainā!

Pasūtījumu pieņemšana 24 stundas dienaktī!

Pasūtījumu pieņemšana 24 stundas dienaktī!

Mēs apstrādāsim jūsu pasūtījumu jebkurā laikā.

Citi
Accessories included - Mounting screws- 1.5V AA type alkaline batteries
Alarm Sound; Light
Color White
Detector Carbon monoxide
Dimensions 118 x 70 x 40 mm
Environment requirements Temperature range:- 0 ° C ... + 40 ° C: work- -10 ° C ... + 60 ° C: transport and storageHumidity:- up to 90% RH, non-condensing
Other features Certificates and approvals:- PN-EN50291: 1-2010, BSI certification body- CE declaration
Power Batteries / rechargeable AA
Special functions Sensor:- KIDDE Electrochemical CO sensor- Power supply: DC, three AA 1.5V alkaline batteries (supplied)- Mounting: on the wall (mounting screws included) or as a standalone unitSIGNALING:- Exceeded 85 dB acoustic emission limit and optical (red LED), indication of detected concentration on LCD panel- Low power (battery discharge) Lo message on LCD panel, short beep and flashing red LED- Incorrect operation: Err message on the LCD panel, short beep and red LED flashing or continuous alarm in the absence of displayEnd of life: End message on the LCD panel, two short beeps, and two red LED flashes within 30 seconds.Indications on the LCD panel:- Current CO concentration in the range of 0 - 999 PPM- Lo - low power state (discharged batteries)- Err - device malfunction- End - End of sensor operating period- Test / Reset button: to control and operate the device. At the push of a button, the machine performs a control test and, when activated, enables it to be turned off- Peak memory: When pressed, the highest detected CO level is displayed when the sensor memory is reset.Alarm activation times: alarm thresholds according to PN-EN50291-1: 2010:- 30 PPM no alarm before 120min.- 50 PPM must alert within 60-90 minutes.- 100 PPM must alert within 10-40 minutes.- 300 PPM must alert within 3 minutes
Volume 85 dB
Weight 160 g